%0 journal article %@ 1084-7529 %A Donath, T., Beckmann, F., Schreyer, A. %D 2006 %J Journal of the Optical Society of America A %N 5 %P 1048-1057 %R doi:10.1364/JOSAA.23.001048 %T Automated determination of the center of rotation in tomography data %U https://doi.org/10.1364/JOSAA.23.001048 5 %X using the image metrics and compared with the results obtained by the center-of-mass method and by image registration. It is found that the image metrics make it possible to determine the axis position reliably at well below the resolution of one detector bin in an automated procedure.