conference lecture (invited)

Activation and first tests of an industrially sized hydrogen storage system based on ~4 tons of metal hydride coupled to a PCM-based heat storage system

Abstract

Hydrogen storage in solid state materials has, with few exceptions [1], been confined to laboratory-scale test tanks, so that its real potential has not been fully explored yet. This work, carried out during the EU-funded HyCARE project, shows the initial operation of a hydrogen storage system based on approximately 4 tons of a TiFeMn alloy coupled to a phase change material (PCM) in order to store the thermal energy produced during the exothermal hydrogen absorption reaction and use it during the endothermal hydrogen desorption reaction. The main targets of the project were: - Build a low-footprint hydrogen storage system - Demonstrate a hydrogen storage capacity of about 50 kg - Reach an energy loss rate of less than 15 % of the energy contained in the stored hydrogen - Operate at mild conditions of pressure and temperature, i. e. less than 50 bar and less than 90 °C These targets have been achieved within the experimental error, some of them greatly exceeding expectations. The storage system is enclosed in a 20 -foot container (Fig. 1). It is therefore not location-bound and can be used at different places and in different applications. The activation of the hydride, as well as the first test results will be shown.
QR Code: Link to publication